Prairie Stone International

Impact Resistance


Date4/23/2003
Test MethodCCMC Masterformat 07483
Ambient conditionsTemperature: 18 degrees C
Test Method Used Simulated section of wall 8' x 8' (2.44m x 2.44m) mounted vertically in test frame

Impactors suspended by 3.2 m length of rope between impactor and overhead hook to rest against test sample.

Impactor pulled back and up to drop height and released allowing impactor to swing in falling arc until it impacts the sample.

After impact, sample inspected for any cracks, or other damage around impact point.


Safety Impact Tests

Impact Load and Type Drop Height Impact energy Comments/Observations
Large Soft 50 kg bag8 ins (203 mm)100 N.m.No cracks or other damage
No penetration of system
No dislodging of any part of system
No falling debris
No structural damage
Hard 1 kg steel ball40 ins (1.016 m)10 N.m.As Above


Retention of Performance Tests

Impact Load and Type Drop Height Impact energy Comments/Observations
Large Soft 50 kg bag2.7 ins (68.5 mm)34 N.m.No cracks or other damage
No penetration of system
No dislodging of any part of system
No falling debris
No structural damage
Small Soft 3 kg bag80 ins (2.032 m)60 N.m.As Above
Hard 1 kg steel ball40 ins (1.016 m)10 N.m.As Above